TM 9-2330-334-13&P
OVERLOAD INDICATOR DOES NOT OPERATE-Continued
0051 00
THIS WORK PACKAGE COVERS:
Pneumatic System Troubleshooting
Table 1.
Overload Indicator Does Not Operate.
Change 1
0051 00-2
INDICATION/CONDITION
DECISION (NO/YES)
PROCEDURAL STEPS
1.
Is air present at connection
points to gauge at air hoses
018 and 019?
No.
Go to (Indication/Condition
2).
1.
Loosen air hoses 018 and
019 from overload indicator
connection points.
Yes.
Replace Overload Indicator
(WP 0106 00).
2.
Charge air system.
3.
Check to see if air escapes
at connection points of air
hoses.
4.
Tighten air hose connections
at overload indicator.
2.
Do air hoses 018 or 019
have any kinks, leaks or
holes in them?
No.
Proceed to Suspension
System Sits Uneven (WP
0045 00).
1.
Apply soapy water solution
to air hoses 018 and 019
and fittings.
Yes.
Replace air hoses 018
and/or 019.
2.
Check air hoses 018 and 019
between overload indicator
for bubbles indicating holes
or leaks.
3.
Check hoses 018 and 019
for kinks.
END OF WORK PACKAGE