TM 9-2350-238-20-1
2-171. MAINTENANCE OF SPADE HYDRAULIC CONTROL VALVES, LINES, AND
FITTINGS (CONT).
• To avoid injury to personnel, do not
tighten or loosen hydraulic fittings
when system is pressurized.
• Lower the boom to stowed position
before doing any maintenance on
hydraulic system.
• Wipe up any spilled hydraulic fluid
to prevent injury to personnel.
2
3
4
5
6
Install covers on open hydraulic ports,
tubes, and hoses immediately after
disconnecting them to keep dirt out of
hydraulic system.
1
Disconnect metal tube assembly (1) from
elbow (2).
7
8
Remove tube fitting locknut (3) and
preformed packing (4) from elbow (2).
Disconnect nonmetallic hose assembly (5)
and remove elbow (2).
Remove nonmetallic hose assembly (5)
from tube elbow (6).
Loosen tube fitting locknut (7) on tube
elbow (6).
Remove tube elbow (6), tube fitting locknut
(7), packing retainer (8), and preformed
packing (9) from port 1 of right hydraulic
cylinder assembly (10).
Disconnect metal tube assembly (11 ) from
elbow (12).
Remove tube fitting locknut (13) and
preformed packing (14) from elbow (12).
2-980