TM 9-2350-238-20-1
2-171. MAINTENANCE OF SPADE HYDRAULIC CONTROL VALVES, LINES, AND
FITTINGS (CONT).
INSTALLATION
1
Install new preformed packing (1) and tube
reducer (2) on slip ring assembly (3).
2
Install metal tube assembly (4) on tube
reducer (2).
3
Install new preformed packing (5), flat
washer (6), new tube fitting locknut (7),
and tube tee (8) on direct linear valve (9).
4
Tighten tube fitting locknut (7).
5
Connect metal tube assembly (4) to tube
tee (8).
6
Install new preformed packing (10) and
tube nipple (11) to direct linear valve (9).
7
Install metal tube assembly (12) on tube
nipple (11).
8
Install new preformed packing (13), flat
washer (14), new tube fitting locknut (15),
and tube elbow (16) to direct linear valve
(9).
9
Tighten tube fitting locknut (15).
10
Install new preformed packing (17) and
tube nipple (18) to direct linear valve (9).
11
Install metal tube assembly (19) on tube
nipple (18).
12
Install metal tube assembly (20) on tube
elbow (16) and connect to tube tee (8).
2-986