2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Step 8.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Disconnect lead 459A from circuit breaker. Place red probe in circuit
breaker terminal and ground black probe. Set MASTER switch ON. If
multimeter indicates no voltage, replace circuit breaker. Refer to page
2-590. If multimeter indicates about 24 volts, go to step 9. Set MASTER
switch OFF. Connect lead 459A to circuit breaker.
2-108