TM 9-2350-238-20-1
Step 4.
Disconnect leads 415 from circuit breaker. Connect multimeter to circuit
breaker receptacles. If multimeter indicates continuity, go to step 5. If
multimeter indicates infinity, replace circuit breaker. Refer to page 2-584.
Connect leads.
Step 5.
To access generator, remove hull engine compartment deck assembly lid,
refer to page 2-935; and remove radiator support beam, refer to page
2-525. Disconnect lead 3 from generator terminal E-. Check continuity
between lead 3 and ground. If continuity exists, go to step 6. If no
continuity exists, repair or replace lead 3 between generator and ground.
Refer to page 2-371. Connect lead 3 to generator terminal E-.