TM 9-2350-238-20-1
H. GENERATOR OUTPUT CIRCUIT.
Step 1.
To access generator, remove hull engine compartment deck assembly lid,
refer to page 2-935; and remove radiator support beam, refer to page
2-525. Disconnect lead 3 from generator terminal E-. Check continuity
between lead 3 and ground. If continuity exists, go to step 2. If no
continuity exists, repair lead 3 between generator and ground. Connect
lead 3 to generator terminal E-.