TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Step 1.
To access indicators, remove driver's instrument (gage) panel. Refer to
page 2-571. Disconnect lead 27 from XMSN OIL TEMP indicator. Place
red probe in lead 27. Ground black probe. Set MASTER and INST
switches ON. If multimeter indicates no voltage, go to step 2. If
multimeter indicates about 24 volts, go to step 3. Set MASTER and INST
switches OFF. Connect lead 27 to XMSN OIL TEMP indicator.
Step 2.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Disconnect wiring harness from instrument (gage) panel. Place red probe
on pin F (lead 27) of receptacle. Ground black probe. Set MASTER and
INST switches ON. If multimeter indicates no voltage, repair lead 27 from
INST switch to receptacle. Refer to page 2-371. If multimeter indicates
about 24 volts, repair lead 27 from plug to instruments. Refer to page
2-371. Set MASTER and INST switches OFF. Connect wiring harness to
instrument (gage) panel.
2-162