TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 2.
Disconnect wiring harness from instrument (gage) panel. Place red probe
on pin F (lead 27) of receptacle. Ground black probe. Set MASTER and
INST switches ON. If multimeter indicates no voltage, repair lead 27 from
INST switch to receptacle. Refer to page 2-371. If multimeter indicates
about
24
volts, repair lead 27 from plug to instruments. Refer to page
2-371. Set MASTER and INST switches OFF. Connect wiring harness to
instrument (gage) panel.
2-166