TM-9-2350-238-20-1

HULL AND RELATED COMPONENTS RECOVERY VEHICLE, FULL TRACKED: LIGHT, ARMORED, M578

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL

MAY 1994

  TM-9-2350-238-20-1 - Page 348 of 1364

TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Step 10.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Disconnect connector from air intake fan. Place red probe in socket A (lead
344). Ground black probe. Set MASTER switch ON. Set AIR INTAKE
FAN switch ON. If multimeter indicates about 24 volts, go to step 11. If
multimeter indicates no voltage, repair lead 344 between wiring harness
disconnect and air intake fan. Refer to page 2-371. Set MASTER switch
OFF. Set AIR INTAKE FAN switch OFF. Connect connector to air intake
fan.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 11.
Place red probe in socket A (lead 314). Place black probe in socket B
(ground) of air intake fan. Set MASTER switch ON. Set AIR INTAKE FAN
switch ON. If multimeter indicates about 24 volts, notify direct support
maintenance. If multimeter indicates no voltage, repair air intake fan ground
lead. Refer to page 2-371. Set MASTER switch OFF. Set AIR INTAKE
FAN switch OFF. Connect connector to air intake fan.
2-322


Back to Top