TM 9-2350-238-20-1
2-17. TYPICAL MALE-TYPE PANEL MOUNTING RECEPTACLE CONNECTOR (CONT).
REASSEMBLY
1
2
3
4
5
6
7
8
Strip cable insulation equal to depth of
solder wells of pin contacts (1).
Slide nut (2) onto cable (3).
Slide grommet (4) over cable leads (5).
Insert cable leads (5) into solder wells of
pin contacts (1) and solder.
Push insert (6) into shell assembly (7)
from rear until seated. Groove (8) in
insert (6) must be aligned with guide in
shell assembly (7) to ensure proper fit.
Push pin contacts (1) into insert (6) from
rear until seated.
Push grommet (4) down cable leads (5) and
Screw nut (2) onto shell assembly (7).
over solder wells of pin contacts (1).
DISASSEMBLY
1
2
3
4
5
6
2-18. TYPICAL FEMALE-TYPE PLUG CONNECTOR.
Unscrew nut (1) from shell assembly (2)
and slide back on cable (3).
Slide grommet (4) back on cable leads (5).
Slide coupling (6) off shell assembly (2).
Drive socket contacts (7) out through rear
of insert (8) with pin extractor.
Push insert (8) out through rear of shell
assembly (2).
Unsolder cable leads (5) from socket
contacts (7).
2-374