WARNING
TM 9-2350-238-20- 2
2-81. MAINTENANCE OF ELECTRICAL LEVEL WIND SOLENOID TO SENSING SWITC H
AND LEFT RECTIFIER BRANCHED WIRING HARNESS (CONT) .
REMOVA L
•
•
Make sure MASTER switch i s
OFF before repairing electrica l
components. Failure to observ e
this warning could result in in-
jury to personnel .
Failure to remove or disconnec t
the batteries before removing o r
installing any electrical wirin g
harness or lead may result in in-
jury or damaged equipment .
NOT E
Electrical lead tag numbers appear
more than once .
1
Disconnect electrical lead 480 (1) fro m
left level wind sensing switch (2) .
2
Remove all necessary clamps, fasteners ,
and grommets from electrical level wind t o
sensing switch and left rectifier branche d
wiring harness (3) .
3
Disconnect electrical lead 480 (4) fro m
rectifier (5) .
2-266