WARNING
TM 9-2350-238-20- 2
Failure to remove or disconnec t
electrical wiring harness or lea d
1
Install electrical level wind solenoi d
the batteries before removing or installing any
may result in injury or damaged equipment .
to sensing switch and left rectifier branched wirin g
harness (1). Connect ground wire (2) and install using washer (3) and screw (4).
2
Connect electrical lead 480 (5) on solenoid valve (6) .
3
Connect electrical lead 480 (7) on rectifier (8).
4
Install clamps, fasteners, and grommets on electrical level wind solenoid to sensing switc h
and left rectifier branched wiring harness (1) .
5
Connect electrical lead 480 (9) on left level wind sensing switch (10) .
2-26 9