WARNING
WARNING
TM 9-2350-238-24P-2
TM 9-2350-238-20- 2
2-82. MAINTENANCE OF CAB TO SLIP RING GROUND ELECTRICAL LEAD .
REMOVA L
•
•
Make sure MASTER switch i s
OFF before repairing electrica l
components. Failure to observ e
this warning could result in in-
jury to personnel .
Failure to remove or disconnec t
the batteries before removing o r
installing any electrical wirin g
harness or lead may result in in-
jury or damaged equipment .
Remove assembled washer bolt (1) an d
Iockwasher (2) and disconnect cab to slip rin g
ground electrical lead (3) from slip ring (4) .
2-27 0