WARNING
TM 9-2350-238-20- 2
(1) Level wind does not traverse cab when MASTER and LEVEL WIND switches ar e
ON. Filter bypass indicator light is on .
Make sure MASTER switch is OFF before repairing electrical com-
ponents. Failure to observe this warning could result in injury t o
personnel .
Step 1 .
Disconnect lead 480 (1) from input side of LEVEL WIND switch (2). Plac e
red probe in lead 480. Ground black probe. Set MASTER switch ON. I f
multimeter indicates about 24 volts, go to step 2. If multimeter indicates n o
voltage, repair lead 480 between LEVEL WIND switch and circuit breaker ,
refer to page 2-66. Set MASTER switch OFF. Connect lead .