2-28. MAINTENANCE OF BOOM AND WINCH–CONTROL CYLINDERS AND AT-
TACHING PARTS AND BOOM CONTROL CYLINDER ASSEMBLY (CONT).
BOOM DROP RATE TEST
●
Make sure alll personnel stand clear when operating boom to avouid injury to per-
l
sonnel.
●
When testing hydralic system, be sure boom is in stowed position as failure of
system may result in injury of personnel .
1
1
2
3
4
5
Turn off hydraulic syste,m (TM 9-2350-238-10
Using thermometer, measure and record temperature of hydraulic fl;uid Tm 9-2350-20-2
Hydraulic syustem is under high pressure.
Follow hydraulic system, safety pro-
cedures to prevent injuyry TM 9-2350-238-2 0
Turn on hydraulic system (TM
9-2350-238-10).
Set boom winch shift control lever (1) to
LO.
Push in BOOM WINCH BRAKE PRESSURE
SELECTOR knob (2).
2-98