CEP BIT FAULT CODES - Continued
Table 1.
CEP Display LED Description and Operation - Continued.
DESCRIPTION
LED
OPERATION
3.
Steady, when extinguishers are either not connected, have
low pressure, have an open-valve solenoid, disconnected
harness, or valve.
4.
Blinking, in sequence, for duration of BIT.
5.
Blinking, at a 2 Hz rate, when extinguisher discharged
properly. This discharge information is stored, even after
power is removed. Discharge information should be manually
cleared only when a good extinguisher (sufficient pressure
and valve continuity) is connected and RESET button
is pressed.
NOTE
•
Double blinking will not start until 5 seconds
after extinguisher activation. This information
is stored, even after power is removed, and
manually cleared only when a good
extinguisher (sufficient pressure and valve
continuity) is connected and RESET button
is pressed.
•
Do not press RESET button prior to replacing
any extinguisher. This replacement must be
performed in this order or non-performing
extinguisher(s) indistinguishable by future
BIT, may be placed into service.
6.
Double blinking, when an extinguisher experiences a flow
failure, LED repeatedly double blinks and then pauses.
Engine 2nd Shot
Extinguisher
E3 and E4
Engine 2nd shot EXTINGUISHER LEDs illuminate during the
following conditions:
1.
Steady, when BIT/LAMP TEST switch is pressed
(5 seconds maximum).
2.
Steady, when extinguishers are not connected, have low
pressure, or have an open-valve solenoid.
3.
Blinking, in sequence, for duration of BIT.
END OF TASK
TM 9-2350-256-10
0051
0051-5