CEP BIT FAULT CODES - Continued
Table 1.
CEP Display LED Description and Operation - Continued.
DESCRIPTION
LED
OPERATION
3.
Steady, when extinguishers are either not connected, have
low pressure, have an open-valve solenoid, disconnected
harness, or valve.
4.
Blinking, in sequence, for duration of BIT.
5.
Blinking, at a 2 Hz rate, when extinguisher discharged
properly. This discharge information is stored, even after
power is removed. Discharge information should be manually
cleared only when a good extinguisher (sufficient pressure
and valve continuity) is connected and RESET button
is pressed.
NOTE
Double blinking will not start until 5 seconds
after extinguisher activation. This information
is stored, even after power is removed, and
manually cleared only when a good
extinguisher (sufficient pressure and valve
continuity) is connected and RESET button
is pressed.
Do not press RESET button prior to replacing
any extinguisher. This replacement must be
performed in this order or non-performing
extinguisher(s) indistinguishable by future
BIT, may be placed into service.
6.
Double blinking, when an extinguisher experiences a flow
failure, LED repeatedly double blinks and then pauses.
Engine 2nd Shot
Extinguisher
E3 and E4
Engine 2nd shot EXTINGUISHER LEDs illuminate during the
following conditions:
1.
Steady, when BIT/LAMP TEST switch is pressed
(5 seconds maximum).
2.
Steady, when extinguishers are not connected, have low
pressure, or have an open-valve solenoid.
3.
Blinking, in sequence, for duration of BIT.
END OF TASK
TM 9-2350-256-10
0051
0051-5