FIXED FIRE EXTINGUISHER SYSTEM (FFES) OPERATION, IF EQUIPPED
INITIAL SETUP:
Not Applicable
WARNING
The CO
2
fire extinguisher can cause suffocation and severe burns. Exit vehicle
immediately after discharging fire extinguisher. Failure to comply may result in personnel
death or injury.
GENERAL
The Fixed Fire Extinguisher System (FFES) contains two banks of four cylinders each. Each bank discharges
CO
2
into engine and hydraulic compartments. The FFES will put out electrical, hydraulic, and fuel-type fires in the
hydraulic and engine compartments. Two sets of pull handles are used to discharge the FFES. One set is located
inside crew compartment on left-hand wall behind the operator. The other set is located outside, on operator side
of vehicle. Each handle in a set of pull handles will discharge one of the banks of cylinders. In addition to two sets
of pull handles, there are manual discharge levers on top of two rear left-side cylinders. These levers may be
used if pull handles malfunction or are not accessible.