AFES CONTROL ELECTRONICS PANEL (CEP) OPERATION
1.
Place vehicle MASTER switch (WP 0004) in ON position. CEP (Figure 1, Item 1) will automatically run a
Built-In Test (BIT) during which all status LEDs illuminate a sequence for eight seconds followed by a
SYSTEM ON LED (Figure 1, Item 3) lighting.
2.
Monitor CEP (Figure 1, Item 1) displays signs of a system fault. Alarm Control Box (ACB) will also sound a
warning if CEP has detected a system fault. If sensor LED (S1-S5) or EXTINGUISHER LED (E1-E5)
remains on or blinks perform AFES troubleshooting procedures (WP 0082).
END OF TASK
AFES CEP SHUTDOWN
1.
Place vehicle MASTER switch (WP 0004) in OFF position.
NOTE
AFES will remain active for 30 minutes unless CEP MAINTENANCE (MAINT) switch
is pressed.
2.
Push CEP MAINTENANCE (MAINT) switch (Figure 1, Item 2) if performing AFES service, maintenance,
or repair.
Figure 1.
AFES CEP Operation.
END OF TASK