TM-9-2350-256-10

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

OPERATOR'S MANUAL

OCTOBER 2014

  TM-9-2350-256-10 - Page 474 of 796

AUXILIARY HYDRAULIC SYSTEM WILL NOT WORK
SYMPTOM
Auxiliary hydraulic system will not work.
MALFUNCTION
Oil level in hydraulic oil tank is low.
CORRECTIVE ACTION
WARNING
Hot engine surfaces can ignite engine oil. Clean oil from around oil filler tube
area with wiping rags after filling. Ensure engine oil filler tube cap is tight and
engine oil fill access door is closed and latched. Failure to comply may result in
personnel death, injury, and/or damage to equipment.
1.
Check oil level in hydraulic oil tank (WP 0099).
2.
Fill oil in hydraulic oil tank to appropriate level (WP 0099).
3.
Start APU (WP 0042) and operate hydraulic system (WP 0074).
4.
If problem still exists, notify maintenance.
BOOM AND SPADE WILL NOT WORK WITH APU ENGINE RUNNING
SYMPTOM
Boom and spade will not work with APU engine running.
MALFUNCTION
APU EMERGENCY WINCH CONTROL valve is in wrong position.
CORRECTIVE ACTION
1.
Check APU EMERGENCY WINCH CONTROL valve position (WP 0074).
2.
Turn valve to NORMAL OPERATION position (WP 0074).
3.
Attempt to operate boom (WP 0078) and/or spade (WP 0075) with APU engine running.
4.
If problem still exists, notify maintenance.
END OF WORK PACKAGE
TM 9-2350-256-10
0086
0086-4