WARNING FAULTS - Continued
corrected, heater will continue to operate until an unsafe condition or component failure fault occurs. Heater will
automatically shut down and a failure code will be displayed on the diagnostic display.
Refer to Table 1, Warning Faults. If heater displays a warning fault not listed in Table 1, notify maintenance.
SHUTDOWN FAULTS
If during operation, a shutdown fault occurs, the heater will immediately enter the shutdown and purge modes to
avoid operating in an unsafe condition. The diagnostic display will display the fault mode and the control box
indicator lamp will flash in cycle consisting of one flash followed by a two second delay.
Refer to Table 2, Shutdown Faults. If heater displays a shutdown fault not listed in Table 2, notify maintenance.
Table 1.
Warning Faults.
E2
Low Fuel Pressure
F3
Heat Limit
F6
Inlet Overheat
SHUTDOWN FAULTS
Table 2.
Shutdown Faults.
C3
Vent Fan Fault
E1
Low Voltage
E3
Low Burner Air Flow
F1
Ignition Overtime
F2
Burner Flameout
F4
Vent Air Overheat
F7
Exhaust Overheat