TM-9-2350-256-34

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

JULY 2005

  TM-9-2350-256-34 - Page 425 of 584

TM 9-2350-256-34
0076 00
INTERMEDIATE MAINTENANCE
RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1
NSN 2350-00-122-6826, EIC AQA
PRESSURE SWITCH ASSEMBLY
MAINTENANCE
REMOVAL, TESTING, INSTALLATION, ADJUSTMENT
INITIAL SETUP:
Test Equipment
Gage (item 10, WP 0086 00)
Multimeter (item 23, WP 0086 00)
Tools and Special Tools
Tool kit, general mechanic’s (item 34, WP 0086 00)
References
TM 9-2350-256-20
Removal
1.
Remove pressure switch assembly in accordance with TM 9-2350-256-20.
Testing
NOTE
The pressure switch assembly should open when hydraulic pressure of 235 ± 3 psi (1620 ± 21 kPa)
is applied and should close when the pressure drops to approximately 221 ± 8 psi (1524 ± 55 kPa).
Instructions for testing and adjusting the pressure switch assembly are provided below.
0076 00-1


Back to Top