TM 9-2350-260-20-1-3
GENERATOR REPLACEMENT (Sheet 7 of 15)
WARNING
Generator weighs approximately 100 pounds; therefore, two persons are required
to handle generator during removal.
Care must be used to prevent damage to
splined shaft and housing when removing generator.
28. Using hydraulic jack, support generator (F).
29. Rotate generator (F) counterclockwise (in direction of arrow) until self-locking nuts (AG) aline with elongated holes in
mounting flange (AH).
30. Slide generator (F) away from drive adapter (AJ) until drive shaft is disengaged.
31. Remove generator (F) and flexible boot (J) and place on work bench.
Go on to Sheet 8
TA147045
10-13