TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 32 of 783

TM 9-2350-260-20-1-3
GENERATOR REPLACEMENT (Sheet 14 of 15)
24. Position generator duct (AK) on generator (F).
25. Using 1/2 inch wrench, install two screws (AL), new lockwashers (AM), and flat washers (AN) securing generator duct
(AK) to engine.
26. Slide clamp (AP) on generator duct (AK).
27. Position flexible connector (AQ) on generator duct (AK).
28. Position clamp (AP) on flexible connector (AQ).
29. Using screwdriver, turn screw (AR) to secure clamp (AP).
WARNING
Wear protective goggles when
polarizing the generator because
sparks may fly into your face.
NOTE
Polarize the generator.
Using a 6-24
vdc power source, connect positive
(+) lead of power source to generator
terminal (AS).
Touch negative (-) lead
of
power
source
to
generator
terminal (AT) for a period of less than
five seconds.
Disconnect positive
lead from generator terminal (AS).
Go on to Sheet 15
TA147052
10-20


Back to Top