TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 39 of 783

TM 9-2350-260-20-1-3
VOLTAGE CONTROL BOX REPLACEMENT (Sheet 1 of 2)
TOOLS: 7/16 in.
combination box and open end wrench
Spanner wrench
REFERENCE:
TM 9-2350-260-10
SUPPLIES:
Lokwasher (MS35338-44) (2 required)
PRELIMINARY PROCEDURES:Open turret platform access door (TM 9-2350-260-10)
Traverse turret to gain access to voltage
control box (TM 9-2350-260-10)
REMOVAL:
1.
Using spanner wrench, disconnect electrical connector (A) from voltage control box (B).
NOTE
Screws and lockwashers (C) securing voltage control box (B) are located under the
voltage control box.
2.
Using 7/16 inch wrench, remove two screws and lockwashers (C) securing voltage control box (B) to bracket.
Throw
lockwashers away.
3.
Remove voltage control box (B) from mounting bracket and tank.
Go on to Sheet 2
TA147059
10-27