TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 265 of 761

TM 9-2350-261-10
OPERATE PERSONNEL HEATER — Continued
0036 00
4.
Make sure HI-LO switch is set to LO before starting.
NOTE
On the majority of the heater control boxes, the control light comes on dimmed during start
cycle of the heater. When heater starts the light goes to full brightness.
5.
Move RUN-OFF-START switch to START for 2 minutes. If HEATER light does not come on, move RUN-OFF-START
switch to OFF for 10 seconds. Move RUN-OFF-START switch to START for 1 minute. If HEATER light does not come
on, move RUN-OFF-START switch to OFF for 10 seconds. Move RUN-OFF-START switch to START for 1 minute. If
heater fails to start after third try, troubleshoot heater (WP 0074 00).
6.
Move RUN-OFF-START switch to RUN as soon as HEATER light comes on. Do not stop in OFF position.
7.
Move RUN-OFF-START switch to START for 4 minutes. If HEATER light does not come on, move RUN-OFF-START
switch to OFF. Wait at least 15 minutes. Move RUN-OFF-START switch to START for 4 minutes. If heater fails to
start after second try, troubleshoot heater (WP 0074 00).
8.
Move RUN-OFF-START switch to RUN as soon as HEATER light comes on. Do not stop in OFF position.
003600-3