TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 279 of 761

TM 9-2350-261-10
OPERATE FIXED FIRE EXTINGUISHER SYSTEM
0040 00
THIS WORK PACKAGE COVERS:
Operate Fixed Fire Extinguisher (Outside) (page 0040 00-1).
Operate Fixed Fire Extinguisher (Inside) (page 0040 00-2).
INITIAL SETUP:
Maintenance Level
Operator
Personnel Required
Driver or soldier
References
WP 0029 00
Equipment Condition
Fire extinguisher installed and seal unbroken
OPERATE FIXED FIRE EXTINGUISHER (OUTSIDE)
WARNING
If CO² is discharged into engine compartment while engine is running, engine exhaust may be
poisonous. Poisonous gas can injure you. Stop engine before you discharge CO². If CO² is
discharged while engine is running, do not breathe engine exhaust.
Engine fan can blow away CO² before fire is extinguished. Personnel can get burned.
Equipment can get damaged. Stop engine before you operate fire extinguisher.
NOTE
Unit maintenance should be notified after fixed fire extinguisher is discharged.
1.
Stop engine (WP 0029 00).
004000-1