TM 9-2350-261-10
MAINTENANCE OF AIR CLEANER
0089 00
THIS WORK PACKAGE COVERS:
Removal (page 0089 00-1).
Cleaning (page 0089 00-2).
Installation (page 0089 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Personnel Required
Driver
References
DA Form 2404
WP 0014 00
WP 0047 00
Equipment Condition
Engine stopped (WP 0029 00)
REMOVAL
WARNING
Failure to decontaminate and wear protective clothing after NBC attack could result in serious
health hazards to personnel. Do not service air cleaner or vent system after NBC attack until
carrier has been decontaminated.
If NBC exposure is suspected, all air filter medial should be handled by personnel wearing
protective equipment. Consult your unit NBC officer or NBC NCO for appropriate handling
or disposal instructions.
Unlatched hatch covers can swing and injure personnel. Make sure hatches are latched open or
closed.
CAUTION
Operating carrier with air cleaner missing or damaged can cause extensive engine damage. Do
not operate carrier if air cleaner element is missing or door or gasket is missing or damaged.
NOTE
You will have one of two air cleaner configurations. Body and elements are not interchangeable
except as sets.
1.
Lower trim vane (WP 0047 00).
2.
Open power plant access door (WP 0014 00).
008900-1