TM 9-2350-261-10
MAINTENANCE OF AIR CLEANER — Continued
0089 00
INSTALLATION
NOTE
If filter element cannot be cleaned satisfactorily by jarring, record fault on DA Form 2404 and
report it to unit maintenance. Unit maintenance will clean the filter element by either the
recommended air hose or washing method.
1.
Install filter element in air cleaner body. Turn the filter element until the slot on the bottom is between stops in the air
cleaner body.
NOTE
Drain hole in air cleaner body must be positioned as shown to align latches.
2.
Secure air cleaner body to cover with four latches.
3.
Close power plant access door (WP 0014 00).
4.
Stow trim vane (WP 0047 00).
END OF TASK
0089 00-3/4 blank