REPLACE DISTRIBUTION BOX ASSEMBLY FOR 200 AMP GENERATOR
SYSTEM (M901A1 ONLY) — Continued
10. Install two new grommets (1) and (2), cable assembly W8 lead (3), and circuit 49 lead (4). Install circuit 49 lead (5) and
cable assembly W8 leads (6) and (7) on bus bar (8). Secure with new lockwasher (9) and screw (10).
11. Install new grommet (11) and circuit 10, 14, 15, and 27E lead (12) in distribution box (13). Install circuit 10, 14, 15, and
27E lead (14) and circuit 450A lead (15) on bus bar (8). Secure with new lockwasher (16) and screw (17).
12. Install new grommet (18) and circuit 6 lead (24) in distribution box (13). Install circuit 6 lead and cable assembly W8
leads (20) and (21) on bus bar (8). Secure with new lockwasher (22) and screw (23).
0271 00-6
0271 00
TM 9-2350-261-20-2