TM 9-2350-261-20-2
REPLACE THERMOSTAT, HOUSING, AND DEAERATION ELBOW
0200 00
THIS WORK PACKAGE COVERS:
Removal (page 0200 00-1).
Installation (page 0200 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Socket Wrench Set (WP 0780 00, Item 96)
Torque Wrench (WP 0780 00, Item 102)
Materials/Parts
Sealing compound (WP 0782 00, Item 65)
Sealing compound (WP 0782 00, Item 62)
Deaeration elbow gasket
Housing gasket
Key washer (2)
Lockwasher (6)
Thermostat gasket
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked
Trim vane lowered and power plant front access door
open (see your -10)
Cooling system drained (WP 0193 00)
Remove air cleaner housing and element (WP 0185 00)
REMOVAL
1.
Loosen two clamps (1). Disconnect hose (2) from elbow (3) and hose (4) from elbow (5).
020000-1