TM-9-2350-261-20-3

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 3 OF 4

  TM-9-2350-261-20-3 - Page 658 of 932

TM 9-2350-261-20-3
REPLACE/REPAIR HYDRAULIC TANK — Continued
0585 00
FOLLOW-THROUGH STEPS
WARNING
Loose clothing is dangerous around moving belts and pulleys. You could get badly hurt if your
clothes get caught in moving parts.
WARNING
An inoperable/unsafe ramp can fall and kill soldiers. Seal off area behind ramp during testing
and bleeding of hydraulic lines.
1.
Start engine (see your -10). Check for hydraulic leaks.
2.
Raise and lower ramp several times to bleed air from system (see your -10).
3.
Install driver’s power plant access panel (WP 0430 00).
4.
Install power plant rear access panel (WP 0431 00 or WP 0433 00).
5.
Raise and lock ramp (see your -10).
6.
Stop/shutdown engine (see your -10).
END OF TASK
0585 00-8