TM 9-2350-261-20-3
REPLACE QUICK DISCONNECT AND RAMP CONTROL VALVE TUBE TO
BULKHEAD CONNECTION — Continued
0587 00
REMOVAL
1.
Remove four screws (1), washers (2), and clamps (3) on tube (4), and clamp (5) on tachometer cable (6) from four
bulkhead weldnuts.
2.
Remove four clamps (3) from tube (4).
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
3.
Remove tube (4) from ramp control valve (7) and quick disconnect (8).
4.
Remove four locknuts (9), clamps (10), and screws (11) from power plant compartment bulkhead. Discard locknuts.
5.
Remove tube (4) from ramp control valve (7) and bulkhead elbow (12).
0587 00-2