TM-9-2350-261-20-3

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 3 OF 4

  TM-9-2350-261-20-3 - Page 672 of 932

REPLACE RAMP PUMP — Continued
FOLLOW-THROUGH STEPS
1.
Fill transfer gearcase (WP 0120 00).
2.
Fill hydraulic tank (WP 0585 00).
3.
Start engine (see your -10). Check for hydraulic leaks.
4.
Raise and lower ramp several times to bleed air from system (see your -10).
5.
Install power plant rear access panel (see your -10).
6.
Raise and lock ramp (see your -10).
7.
Stop engine (see your -10).
END OF TASK