REPLACE RAMP CONTROL VALVE AND FITTINGS — Continued
0589 00
REMOVAL
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
1.
Disconnect tube (1) from elbow (2).
2.
Disconnect quick disconnect (3) with hose (4) from quick disconnect (5) on control valve.
3.
Disconnect elbow (6) from elbow (7).
4.
Remove nut (8), washer (9), and handle (10) from valve (11).
0589 00-2