REPLACE RAMP CONTROL VALVE AND FITTINGS — Continued
1.
Apply sealing compound to clean male tapered threads of adapter (12).
2.
Install adapter (12) and new preformed packing (13) on valve (3).
3.
Install quick disconnect (14) on adapter (12).
4.
Install elbow (9) and new preformed packing (11) on valve (3). Secure with washer (10) and nut (8).
058900-5
0589 00
TM 9-2350-261-20-3