TM 9-2350-261-20-4
REPLACE M13 PRECLEANER AND FRAME (M1068 ONLY) — Continued
0680 00
INSTALLATION
NOTE
Theprecleanermustbeadjustedbeforeinstallation
.SeeTM3-6680-316-10
.
1.
Install new lockwashers (1), four screws (2), and frame (3) on mounting bracket (4).
2.
Install precleaner (5) in frame (3) and secure with latch (6).
3.
Install two hoses (7) and (8) and clamps (9) on precleaner (5). Tighten clamps.
4.
Install circuit lead 538A (10) with ground lead (11) on precleaner (5).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
END OF TASK
0680 00-2