TM-9-2350-261-20-4

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 4 OF 4

  TM-9-2350-261-20-4 - Page 309 of 767

TM 9-2350-261-20-4
REPLACE SMOKE GENERATOR SYSTEM POWER SUPPLY CABLE
ASSEMBLY (M1059 ONLY) — Continued
0699 00
3.
Install new grommet (8) on cable assembly (1). Route cable through hole in battery box (9).
4.
Install cable assembly lead (10) on positive battery terminal (11). Secure with screw (12) and nut (13).
5.
Install ground lead (14) on clean, paint-free hull bracket. Secure with screw (15), new lockwasher (16), two washers
(17), and new locknut (18).
6.
Connect cable assembly (19) to control panel assembly connector 1J1 (20).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Set circuit breaker CB1 to ON. See TM 3-1040-283-10.
END OF TASK
0699 00-4


Back to Top