TM 9-2350-261-20-4
REPLACE AIR COMPRESSOR ASSEMBLY (M1059 ONLY) — Continued
0704 00
REMOVAL
WARNING
Before you do any maintenance, discharge all capacitors to ground or electrical shock could
injure personnel.
1.
Disconnect air compressor electrical cable assembly (1) from compressor cable assembly connector (2).
WARNING
Compressed air pressure from smoke generator can cause serious injury or death. To avoid
accidents, bleed air before working on air compressor assembly or disconnecting any air hose.
2.
Disconnect two air lines (3) from two compressor air reservoir fittings (4). Install safety caps (5) on lines and dust
covers (6) on fittings.
3.
Remove eight screws (7), lockwashers (8), washers (9), washers (10), and compressor unit (11) from carrier. Have
helpers assist. Discard lockwashers.
0704 00-2