TM 9-2350-261-20-4
REPLACE SMOKE GENERATO R A DAPTER ACCESS PLATE
AND GASKET (M1059 O
NLY)
07 08 00
TH IS WORK PAC KAGE COVER S:
Rem oval ( page 07 08 00 -1 ).
In st allat ion ( pag e 0 708 0 0-3 ).
INITIAL S ETUP:
Maintenance Level
Unit
Tools and Special Tools
G eneral M echanic’s Too l Kit ( WP 078 0 00, Item 29)
Materials/Parts
Lo cknu t (8)
Lockwasher (6)
Personnel Required
U nit M echanic
Equipment Condition
En gin e sto pped ( see y our -10 )
Carrier blocked (see your -10)
C ircu it breaker C B 1
to
OFF (TM 3 -10 40-28 3-1 0)
Battery ground lead disconnected (WP 0294 00)
A ir p ressure released from com pressor reservoir
(TM
3 -1 040 -28 3-20& P)
Inboard armor shield lowered (WP 0713 00)
Smoke generator assembly removed from bracket
(WP 0697 00)
REMOVAL
WARNING
Compressed air pressure from smoke generator can cause serious injury or death. To avoid
accidents, bleed air before working on air compressor assembly or disconnecting any air hose.
WARNING
Before you do any maintenance, discharge all capacitors to ground or electrical shock could
injure personnel.
070800-1