TM 9-2350-261-20-4
REPLACE SMOKE GENERATOR COMPRESSOR RESERVOIR TO ADAPTER
ACCESS PLATE AIR HOSE (M1059 ONLY) — Continued
0709 00
INSTALLATION
1.
Secure air hose (1) to carrier hull with three clamps (6), new lockwashers (5), and screws (4).
2.
Connect air hose (1) to adapter plate fitting (3).
3.
Connect air hose (1) to compressor reservoir fitting (2).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Set circuit breaker CB1 to ON. See TM 3-1040-283-10.
END OF TASK
0709 00-3/4 blank