TM 9-2350-261-20-4
REPLACE CABLES W42, W43, AND W251 (M1068 ONLY)
0753 00
THIS WORK PACKAGE COVERS:
Removal (page 0753 00-1).
Installation (page 0753 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Tie strap (6)
Personnel Required
Power-Generation Equipment Repairer 52D10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Release catch (1) and open cover (2) on power supply storage box (3).
2.
Disconnect cable W251 plug P1 (4), cable W42 plug P1 (5), and cable W43 plug P1 (6) from UPS (7). Remove cables
from opening (8) in back of power supply storage box (3).
3.
Remove six tie straps (9) from cables (10). Discard tie straps.
4.
Disconnect cable W251 plug P2 (11) from UPS power extension box A18 jack J6 (12).
5.
Disconnect cable W42 plug P2 (13) from DC power extension box A8 jack J21 (14).
6.
Disconnect cable W43 plug P2 (15) from AC power extension box A7 jack J6 (16).
7.
Remove cables W251 (17), W42 (18), and W43 (19) from carrier.
075300-1