TM-9-2350-261-20-4

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 4 OF 4

  TM-9-2350-261-20-4 - Page 563 of 767

TM 9-2350-261-20-4
REPAIR M8 CHEMICAL ALARM JUNCTION BOX (M113A2 ONLY) — Continued
0774 00
DISASSEMBLY
1.
Remove screw (1) and lead (2) from circuit breaker (3).
2.
Remove two screws (4), locknuts (5), from circuit breaker (3) and distribution box (6). Remove circuit breaker. Discard
locknuts.
3.
Remove screws (7), locknut (8), and terminal board (9) from distribution box (6). Discard locknut.
4.
Remove four locknuts (10), screws (11), and receptacle (12) from distribution box (6). Discard locknuts.
0774 00-2