TM-9-2350-261-34

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-261-34 - Page 512 of 785

TM 9-2350-261-34
INSTALL ENGINE COOLANT HEATER KIT (M1064 ONLY) — Continued
0061 00
117. Replace standard generator belts with kit belts (see your -20).
118. Replace standard fan drive belts with kit belts (see your -20).
119. Adjust belts (see your -20).
120. Open heater fuel valve (1).
FOLLOW-THROUGH STEPS
1.
Install personnel heater (see your -20).
2.
Lower power plant grille (see your -20).
3.
Fill carrier cooling system (see your -20).
4.
Connect battery ground lead (see your -20).
5.
Bleed coolant heater fuel line (see your -20).
6.
Start coolant heater (see your -10). Check for leaks and proper operation. Turn coolant heater off.
7.
Install front floor plates (see your -20).
8.
Install driver’s power plant access panel (see your -20).
9.
Install power plant rear access panel (see your -20).
10. Close power plant front access door andraisetrimvane(seeyour-10)
.
11. Raise and lock ramp (see your -10).
12. Stop engine (see your -10).
END OF TASK
0061 00-23/24 blank


Back to Top