TM 9-2350-261-34
REPAIR AC POWER EXTENSION BOXES A6 AND A7 (M1068 ONLY) — Continued
0080 00
ASSEMBLY
1 .
In stall f our co nnectors ( 1) and d ust caps (2 ) on cov er (3 ) and s ecure with
16
screws (4) and new l ockn uts (5 ).
2.
Install connector J1 (6) on extension box (7) and secure with four screws (8) and new locknuts (9).
3.
Connect leads to connectors if necessary.
4.
Install gasket (10) and cover (3) on extension box (7) and secure with four screws (11).
NOTE
Color Designation for Terminals:
H (HOT) = YELLOW
N (NEUTRAL) = WHITE
G (GROUND) = GREEN
0080 00-2