TM 9-2350-261-34
REPLACE RF 1, 2, 3, 4 CABLE ASSEMBLIES W111, W112, W113, AND
W114 (M1068 ONLY) — Continued
0093 00
3.
Connect W111 plug P1 (1) to jack J115 (2) on signal patch panel box (3).
4.
Connect W112 plug P1 (4) to jack J116 (5) on signal patch panel box (3).
5.
Connect W113 plug P1 (6) to jack J117 (7) on signal patch panel box (3).
6.
Connect W114 plug P1 (8) to jack J118 (9) on signal patch panel box (3).
7.
Connect harness to inside of faceplate (12) of external communications box (11).
8.
Connect W111 plug P2 (13) to jack J115 (14) on faceplate (12).
9.
Connect W112 plug P2 (15) to jack J116 (16) on faceplate (12).
10. Connect W113 plug P2 (17) to jack J117 (18) on faceplate (12).
11. Connect W114 plug P2 (19) to jack J118 (20) on faceplate (12).
0093 00-4