TM-9-2350-261-34

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-261-34 - Page 729 of 785

INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT
(M113A2 ONLY) — Continued
23. Remove four C-clip retainers (1) and backshells (2) from four leads (3).
24. Remove coupling nut (4), spring tension washer (5), retainer (6), bushing (7), nut (8), lockwasher (9), flat washer (10),
and insulator washer (11) from harness (12).
25.
Insert harness (12) through hole in
carrier
to p plate. Have h elper assist.
26. Install insulator washer (11), flat washer (10), lockwasher (9), nut (8), bushing (7), retainer (6), spring tension washer
(5), and coupling nut (4) on harness (12).
27. Install four backshells (2) and C-clip retainers (1) on leads (3).
28. Attach wiring harness (13) to bracket (14) with four screws (15) and new locknuts (16).
29. Attach four leads (3) to leads (17) as follows:
509E to 509G
509F to 509H
6D POS to 6E POS
7D NEG to 7E NEG
3 0.
In stall bracket (14) on
carrier
with fo ur screws ( 18 ) and wash ers (19 ).
0098 00-8
0098 00
TM 9-2350-261-34