16.
R em ove tw o screws (5) and washers ( 4) from hull.
1 7.
Place junction b ox ( 3) on h ull. S ecure w ith two washers (4) an d scr
ews (5). TIGHTEN SCREWS TO 72-78
LB
-
IN
(8 -9 N·M) TO R QU E. Use torque wrench (WP 0 104 0 0, I tem 57).
18. Route alarm unit cable (1) over cradle (2) and along main wiring harness.
19. Connect wiring harness (22) plug (23) to jack on bottom of junction box (5).