INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT
(M113A2 ONLY) — Continued
0098 00
4 .
Rem ove fo ur screws (4) an d washers ( 3) from overhead .
5.
Place alarm spare battery bracket (6) on overhead. Secure with four washers (3) and screws (4). TIGHTEN SCREWS
TO 264 -2 88
LB
-
IN
(3 0-33 N·M) TO R QUE. Use torque wrench (WP 0 104 0 0, I tem 5
8).
6.
Install strap (5) on alarm spare battery bracket (6).
7 .
Rem ove tw o screws (3 ) and washers ( 2) fro m left hu ll plate.
8.
Install bracket (1) with two screws (3) and washers (2) to hull.
9.
Inst all screw (4), tw o washers (5), and l ockn ut (6]) to bracket (1 ).
009800-3