TM 9-2350-261-34
SERVICE CHEMICAL FIRE EXTINGUISHER (M1059 ONLY) — Continued
0097 00
10. Remove nozzle (7) from holder (8) and lift hose (9) from behind puncture lever (10).
11. Operate puncture lever (10) to check for proper working order.
12. Check the pressure relief vent (11) for obstructions.
13. Remove cartridge receiver gasket (12) and check for cuts or wear. If damaged, replace.
0097 00-4