SERVICE CHEMICAL FIRE EXTINGUISHER (M1059 ONLY) — Continued
2.
Return extinguisher (1) to upright position.
3.
Inspect visual inspection seal wire (5) for security.
4.
Examine outer components for cleanliness and corrosion or damage.
5.
Check exterior shell (6), cartridge guard (7), cartridge receiver (3), hose (4), nozzle (2), and handle assembly (8) for
wear or other disorders.
6.
Check nameplates (1) for legibility and security. If nameplate is loose, remove and examine mounting area on shell
(2) for corrosion.
7.
Pull cartridge guard (3) from extinguisher (4). Inspect the inside components for working order and cleanliness.
8.
Unscrew cartridge (5) left hand thread (counterclockwise). Check seal (6) for punctures.
WARNING
A cartridge can be punctured if the lever does not work freely. Do not install the cartridge
before you make sure the puncture lever works freely.
0097 00-2
0097 00
TM 9-2350-261-34